Abstract

Direct current tests performed in the past on the conductor samples of the toroidal field (TF) ITER coils revealed degradation of current sharing temperature, T cs. The degradation progresses with repetitive electromagnetic loading, and also with thermal cycles between 4.5 K and room temperature. This feature was observed on short samples in SULTAN test facility (EPFL-SPC, Switzerland) as well as in TF Insert Coil tests in CSMC test facility (Naka, Japan). We present three independent observations suggesting that initiation of sample quench followed by a fast current discharge, which normally complements every I c and T cs test in both SULTAN and CSMC, enhances the T cs degradation rate. The exact mechanism of this contribution to the degradation remains unidentified.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.