Abstract

The Lapp & Powers (L&P) fault-tree model of a nitric acid cooling process is explored to a greater level of depth than in the previous round-robin correspondence on the controversy over exclusive-or (XOR) gate G7 in the L&P fault tree. In this paper, the minimalized logic equations for success or failure of G7 are derived, and the subsystem reliability function is calculated. The subsystem reliability vs component reliability function is U-shaped; this is not an abnormality, but a result of the XOR failure logic. The overall system reliability vs component reliability function, however, is J-shaped. Some further comments are made on the relevance of this problem to the study of s-noncoherent and fail-safe systems.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.