Abstract
A simple technique is proposed to synthesise the cogging torque waveform of a permanent magnet machine from the cogging torque which is associated with a single stator slot. An analytical expression is derived and applied to two motors, each of which has a fractional number of slots per pole. It is shown that the resultant cogging torque waveform can be synthesized to a high accuracy, as confirmed by both finite element analysis and measurements. It is also shown that not all the cogging torque harmonics which exist in the cogging torque waveform due to a single slot will be present in the resultant cogging torque, and that the most significant components can be identified analytically
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.