Abstract

This paper presents an improved method of current reference determination for a parallel active power filter. To insure sinusoidal line currents, thus reducing reactive power, an integrative method of reference calculation is applied. As a result, satisfactory response of line current to the load change is achieved. One of the major problems, the synchronization to the net voltage, is also considered. Classical solution is based on zero-cross detection of line voltage. Since this approach is very sensitive to the voltage distortions, a new method is suggested, relying on voltage fundamental harmonic calculation. These ideas were tested on a three-phase active power filter, controlled by 32-bit microcontroller.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.