The purpose of this case report is to describe a new surgical method for sutureless placement of the amniotic membrane with a symblepharon ring in a pediatric patient with acute toxic epidermal necrolysis (TEN). A 1-year-old girl developed severe ocular surface inflammation with large corneal and conjunctival epithelial defects secondary to TEN. She was treated by applying a large (4 cm x 4 cm) amniotic membrane graft and non-sterile symblepharon ring under sedoanalgesia at bedside in the intensive care unit. The ocular surface was completely epithelized by post-treatment week 6 in the right and week 8 in the left eye. Two years after amniotic membrane transplantation, both eyes were quiet with no symblepharon, scar formation, or limbal stem cell deficiency. Performing bilateral amniotic membrane transplantation under a symblepharon ring at bedside provided sufficient acute coverage of the ocular surface and led to excellent clinical outcomes by reducing inflammation and protecting the ocular surface.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.