Abstract

We evaluated the use of intraoperative fluorescence guidance by enzymatically cleavable ratiometric activatable cell-penetrating peptide (RACPPPLGC(Me)AG) containing Cy5 as a fluorescent donor and Cy7 as a fluorescent acceptor for salivary gland cancer surgery in a mouse model. Surgical resection of small parotid gland cancers in mice was performed with fluorescence guidance or white light (WL) imaging alone. Tumor identification accuracy, operating time, and tumor-free survival were compared. RACPP guidance aided tumor detection (positive histology in 90% [27/30] vs 48% [15/31] for WL; p < .001). An approximate 25% ratiometric signal increase as the threshold to distinguish between tumor and adjacent tissue, yielded >90% detection sensitivity and specificity. Operating time was reduced by 54% (p < .001), and tumor-free survival was increased with RACPP guidance (p = .025). RACPP provides real-time intraoperative guidance leading to improved survival. Ratiometric signal thresholds can be set according to desired detection accuracy levels for future RACPP applications.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.