Abstract

For development of superconducting conductors and coils, the National Institute for Fusion Science prepared a new superconducting test facility which is a combination of an electro-mechanical testing device and a large cryogenic cooling system at the new Cryogenics and Superconductivity Building at the Toki site. The cryogenic cooling system has a capacity of 250 liters of liquid helium per hour or 500 W at 4.5 K, and can also supply supercritical helium up to 50 g/s. A dc power supply generates 75 kA current at 21 V. A split-type superconducting coil generates a magnetic field of 9 T of 100 mm in width. The mechanical testing machine has a capacity of 10 MN at liquid-helium temperature. The following R & D experiments for the Large Helical Device have been done using the facility: critical current and stability measurement of helical coil conductors of which the nominal current is 21 kA at 7 T, an elasticity measurement of a helical coil, and stability measurement of a cable-in-conduit conductor.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.