Abstract

We previously developed a high powered light-emitting diode device capable of discharging germicidal ultraviolet irradiation (UVA-LED) at an approximate wavelength of 365 nm. This study examined the bactericidal activity of UVA-LED in moving air streams. Aerosols of Escherichia coli DH5alpha were exposed to UVA-LED irradiation using a stable current (0.5 A and 1.2 mW/cm(2)) or pulse current (1.0 A and 0.2 mW/cm(2)). Settle plate analysis was used for bioaerosol sampling, where results were expressed as Colony Forming Units. A -3 Log inactivation of the E. coli population occurred after 75 minutes of constant exposure to stable current. The pulse current produced inactivation within a similar timeframe. Our results might be significant as a basic study for further investigations about the effect of UVA-LED on airborne bacteria and its suitability for air disinfection applications.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.