Abstract

Base (seismic) isolation is a promising technology for seismic protection of buildings and other constructions. Nowadays, it is accepted that such a technique is efficient and reliable; however, it has two major limitations: soft foundation soil, and tall buildings. The first issue restrains the seismic isolation spreading, given that soft soil is frequent in densely populated areas, and usually such a soil type concentrates the highest seismicity levels. This paper aims to contribute to demonstrating that base isolation, if properly implemented, can be suitable for soft soil. A representative case study is analyzed: a 6-story reinforced concrete (RC) building with base isolation that has recently been built in Shanghai. Since the building is founded on soft soil, concern regarding base isolation suitability arose; even the Chinese design code does not recommend this solution for soft soil. To clarify this issue, non-linear time-history analyses are carried out for a number of natural and artificial seismic inputs that represent the site seismicity; the superstructure behavior is linear, while nonlinearities are concentrated in the isolation layer. The adequacy of base isolation is assessed in the superstructure (in terms of reduction of interstory drift, absolute acceleration and shear force) and in the isolation layer (in terms of axial force, torsion angle and shear strain). The relevance of soil–structure interaction is discussed. The behavior when the mechanical parameters of the isolation units have experienced important changes is also analyzed. The major conclusion is that base isolation of ordinary mid-height RC buildings founded on soft soil can perform satisfactorily in medium seismicity regions.

Highlights

  • Base isolation consists in uncoupling the construction under consideration from the foundation soil by using bearings that are flexible in the horizontal direction, being commonly termed as isolators

  • In the framework of this research effort, this paper investigates the rationality of using base isolation for buildings founded on soft soil

  • The displayed results correspond to the seismic inputs in Table 10; the axial force generated by the gravity loads is shown

Read more

Summary

Introduction

Base (seismic) isolation consists in uncoupling the construction under consideration from the foundation soil by using bearings that are flexible in the horizontal direction, being commonly termed as isolators (or isolation units). The resulting structure is divided into three parts: superstructure, isolation layer, and substructure; ordinarily, the isolation layer is situated right below the ground floor slab. Base isolation has been mainly considered for buildings and bridges; this study deals with seismically isolated buildings. The main effect of seismic isolation of buildings is an important elongation of their fundamental period, reducing significantly the spectral ordinate. Given that most of the drift displacement is concentrated in the isolation layer, additional damping can be incorporated; as a result, the spectral ordinate is further lowered.

Objectives
Methods
Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.