Abstract
An efficient pad assignment methodology to minimize voltage drop on a power distribution network is proposed. A combination of successive pad assignment (SPA) with incremental matrix inversion (IMI) determines both location and number of power supply pads to satisfy drop voltage constraint. The SPA creates an equivalent resistance matrix which preserves both pad candidates and power consumption points as external ports so that topological modification due to connection or disconnection between voltage sources and candidate pads is consistently represented. By reusing sub-matrices of the equivalent matrix, the SPA greedily searches the next pad location that minimizes the worst drop voltage. Each time a candidate pad is added, the IMI reduces computational complexity significantly. Experimental results including a 400 pad problem show that the proposed procedures efficiently enumerate pad order in a practical time.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: IEICE Transactions on Fundamentals of Electronics, Communications and Computer Sciences
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.