Abstract

Surface treatment of miniscrews was implemented to determine whether its application increased bone-to-surface contact and enhanced the interlock between the device and the surrounding bone. To compare the success rate of surface-treated and non-treated orthodontic miniscrews used as reinforcement of anchorage during treatment with the Herbst appliance. Split-mouth design with an allocation ratio of 1:1. Eligibility criteria to enrol patients were skeletal and dental class II patients with a retrusive chin, use of the Herbst appliance to correct malocclusion, need for skeletal anchorage using a miniscrew both in the left and right side of the mouth, absence of systemic diseases, absence of using drugs that alter bone metabolism, and good oral hygiene. Patients received self-drilling miniscrews without surface treatment and with surface treatment. Both types presented a 1.4 or 1.2 mm diameter. Miniscrews were inserted between the first molar and second premolars or between the two premolars. The force applied to the screws was an elastic chain from the head of the miniscrews to a direct button applied on the canines. The success rate of each type of miniscrew was considered the primary outcome, and the association of success with demographical, clinical, and geometrical characteristics was investigated. Differences were tested by the generalised linear mixed effects model for the split-mouth design. Differences with a P-value < 0.05 were selected as significant. A randomisation list was created for the mouth side assignment. The study was single blinded with regard to the statistical analysis. Thirty-nine miniscrews of the non-treated type and 39 miniscrews of the surface-treated type were inserted in 39 patients (23 female and 16 male, mean age: 15.55 ± 7.91) recruited between March 2018 and December 2020 with a split-mouth study design. The mean therapy duration was 9.3 months (SD = 1.31). No differences in failure rate were observed between miniscrew types. No serious harm was observed. The success rate of surface-treated and non-treated miniscrews showed no significant differences. This trial was not registered.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.