Abstract

This research paper is a continuation of a prior study [12] that focused on the positive temperature range. The current work investigates the behavior of a laminated Macro Fiber Composite (MFC) piezoelectric transducer when exposed to negative temperatures. The study aims to understand the sensitivity of the transducer under varying ambient temperatures and frequencies, particularly for applications in wireless sensor networks. The integrated Macro Fiber Composite piezoelectric transducer is both theoretically modeled and empirically verified. Experimental tests involve subjecting the laminated MFC piezoelectric transducer to sinusoidal forces generated by an electro-pulse waveform generator, while a thermal chamber is used for temperature control. Controlled displacement is applied to the transducer at low-frequency (5 to 25 Hz) ranges and different moderate temperatures (0 to -40 degrees Celsius). The results highlight the significant influence of temperature and excitation frequency on the generated voltage by the MFC transducer.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.