Abstract

Introduction:Submuscular plating after lengthening shortened the period of external fixation in distraction osteogenesis of the femur. In the femur, where monolateral or ring fixators had been used for the distraction, plates, could be inserted laterally, anteriorly or medially. Specific technical modification of the plate insertion, however, would be necessary to accommodate the femoral varus angular correction created at the end of the distraction, in the pelvic support osteotomy lengthening.Material and Methods:We reviewed a series of eight cases with standard and modified techniques of plating after lengthening. The amount of lengthening, the period of distraction, the external fixator index and the associated complications were assessed.Results:The mean lengthening was 5cm, with a range of 3cm to 9cm. The external fixation index, the period of external fixators in days in relation to the length of distraction in cm, was between 18 days/cm to 58 days/cm. One patient with quadriceps contracture, underwent quadriceplasty to improve knee flexion. Three patients with transient knee stiffness had resolution with aggressive physiotherapy. One patient with transient hypoesthesia recovered spontaneously. None of the patients developed joint subluxation, deep infection, re-fracture or implant failures.Conclusion:Standard and modified techniques of plating after lengthening were safe and required only a short period of external fixation. The modified technique offered an easier way of plate insertion in a deformed bone.

Highlights

  • Submuscular plating after lengthening shortened the period of external fixation in distraction osteogenesis of the femur

  • We reviewed the amount of lengthening; the waiting period which was defined as the time spent

  • The waiting period for case No.[3] took 273 days which was longer than the other cases because plating after lengthening (PAL) had been unplanned, and the patient required Judet quadriceplasty for the knee

Read more

Summary

Introduction

Submuscular plating after lengthening shortened the period of external fixation in distraction osteogenesis of the femur. In the femur, where monolateral or ring fixators had been used for the distraction, plates, could be inserted laterally, anteriorly or medially. Material and Methods: We reviewed a series of eight cases with standard and modified techniques of plating after lengthening. The amount of lengthening, the period of distraction, the external fixator index and the associated complications were assessed. Three patients with transient knee stiffness had resolution with aggressive physiotherapy. One patient with transient hypoesthesia recovered spontaneously. Conclusion: Standard and modified techniques of plating after lengthening were safe and required only a short period of external fixation. Distraction osteogenesis with an external fixator, introduced by Ilizarov, has advanced the management of limb length

Methods
Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.