This article discusses the decrease in flow capacity of valves and nozzles as the temperature of the flowing liquid increases. It was found that the mass flow capacities of both, valves and nozzles will typically decrease to one-third of their value when going from a highly subcooled liquid flow to saturated liquid flow. Test results of subcooled and saturated liquid flow through industrial valves and nozzles are presented. A new mass flow rate model for flow capacity prediction of valves and nozzles exposed to subcooled and saturated liquid flow is developed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.