Abstract

In the present work we demonstrate the development of a thin layer activation (TLA) method to be able to measure micrometer wear or less by using radioactive tracing. In order to activate very swallow depths we decreased the bombarding energy to the “linear” region of the cross-section curve. The disadvantage of the method is that the wear curve will be “linear” near to the surface instead of “constant” as is the case with the usual (high energy) TLA. The advantage is that the activity of the sample will be much lower and it is concentrated in the swallower studied depth. The other possible method is irradiation under small angle (15 to 30° or even grazing incidence), which also causes a near-surface concentration of the activity produced. Both methods are demonstrated with the most suitable nuclear reactions and some commonly used industrial materials.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.