Abstract

Purpose: Current 4D‐CT methods show artifacts of >4 mm in 90% of cases. The purpose of this study was to quantify the impact of audiovisual (AV) biofeedback respiratory training on 4D‐CT image quality. Methods: In an IRB‐approved clinical trial, two 4D‐CT scans, with free breathing and AV biofeedback, were acquired with a cine method for ten thoracic cancer patients. AV biofeedback was based on: (1) a patient‐specific representative waveform and a dot moving according to the abdominal displacement, displayed on the video screen of the goggles; and (2) musical guides provided with a beat period corresponding to the waveform period. The phase‐sorted 4D‐CT images with free breathing and AV biofeedback at the 0% (peak‐inhale), 30%, 50% (peak‐exhale) and 80% phases were analyzed for artifacts by: (1) comparing normalized cross correlation (NCC)‐based scores (artifacts give high scores) of the two images; and (2) quantifying a score for each pair based on visual assessment of the two image sets (positive scores mean that AV biofeedback 4D‐CT is of higher quality). We tested the hypothesis that AV biofeedback significantly reduces 4D‐CT artifacts using the two‐tailed paired t‐test. Results: The impact of AV biofeedback varied widely with patients and phases, suggesting inconsistent patient compliance. For example, patient 5 demonstrated a visual assessment score of 4 at the 0% phase indicating that AV biofeedback 4D‐CT was of higher quality than free breathing, while a score of −3 at the 50% phase indicating the opposite. Overall, no statistically significant differences were found in both the NCC‐based score (free 0.60±0.32 vs. AV 0.65±0.27, p=0.32) and visual assessment score (0.0±2.7, p=0.95). Conclusion: A 10‐patient study demonstrated no statistically significant impact of AV biofeedback respiratory training on 4D‐CT image quality. Future studies will investigate strategies to improve patient compliance by optimizing the biofeedback interface or increasing patient comfort. NIH/NCI 2 R01 CA 093626; Stanford BioX Interdisciplinary Initiatives Program

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.