Abstract

Aim of the study: To study the effect of reduced level of bone support on stress concentration and distribution. Also comparing the effect of different metals (gold, cobalt-chromium, and titanium) on alveolar supporting bone. Material and methods: A FEA method is used on a reduced bone support class I Kennedy classification, with three different rest positions (mesial, distal, mesial and distal) Co-Cr partial denture; Then changing the modulus of elasticity of the chrome-cobalt, to study the effect of gold and titanium alloy on the supporting bone surrounding the abutment in terms of stress distribution. Results: results revealed that best design type is by placing mesial and distal rest on abutment, also when comparing the three types of metals (Co-Cr, titanium, gold), there was no significant difference among the three metals.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.