The impact of the flood discharge water flow from a high dam is rather great on the slab of a plunge pool, and may cause damages to the plunge pool and consequently endangers the dam body safety. Therefore, a reverse arch slab model was established on the base of a study on and a simulation of the rational scale of gaps between the plates of the plunge pool slab. The model was an arch ring containing 7 slabs. The uplift force time history of each slab was measured, and the uplift force power spectrum and probability density were analyzed. The test result shows that the uplift energy mainly centers in 0-15Hz frequency bandwidth, and mostly within 1Hz. It belongs to a low frequency and big amplitude vibration.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.