Abstract

In this paper, the coal ash /refractory samples were sintered in the furnace at certain temperature for 20h. Then three tests were made by visual observation method, XRD analysis of the coal ash and electromagnetic vibration of the coal ash/ refractory samples respectively in this paper to determine the critical temperature of three coal ashes on the corundum based refractories. Finally, the result shows that the electromagnetic vibration test is the most effective method with a better discriminabiltity on slagging intensity to determine the critical temperature of the coal ash slagging on the refractory. And furthermore, it advances a new and reliable method to determine the critical temperature on the refractories.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.