Abstract

According to the problem of low energy utilization of plane spiral coil used in micro-ICP, a kind of micro stereo helical coil was designed. Made 24 different structural parameters of stereo spiral coil whose diameter range 3~10 mm. Using comprehensive experimental method tested different parameters’ coils inspire argon plasma. In 13.56MHz RF power, relationships between argon pressure, coil turns, coil diameter and combustion /maintaining power of micro-ICP excitation source were tested. From spectrometer observed 17 argon emission spectrum in 690~860 nm. Spectral lines intensity influenced by RF power and work pressure. Experiments proved that micro-ICP excitation source using stereo helical coil is feasible. It can form Ar plasma and inspire Ar spectral lines.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.