Abstract

The magnetic flux dissipation from the MgB 2 bulk magnets during pulsed field magnetization (PFM) processes has been estimated for the samples fabricated by hot-pressing (HP) and spark plasma sintering (SPS). We defined the parameters as field penetration ratio B P /B a and the field trapping ratio B T /B P to evaluate the flux motion and performance. The data plots of trapping ratio B T /B P showed us two regions which originate from the fast flux flow and flux jump. The field trapping performance was drastically degraded when the flux jump happened. Flux jump happened at various times after the peak field. A very late flux jump happened at 420 ms which severely degraded the trapped field. This time delay, much larger than the heat propagation time in the MgB 2 sample, remains to be explained.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.