Abstract

This paper presents an investigation of inverter fault-tolerant operation for a permanent magnet synchronous motor (PMSM) direct torque control (DTC) system under various inverter faults. The performance of a faulty standard 6-switch inverter driven PMSM DTC system is analyzed. To avoid the loss or even disaster caused by the inverter faults, a topology-modified inverter with fault-tolerant capability is introduced, which is reconfigured as a 3-phase 4-switch inverter. The modeling of the 4-switch inverter is then analyzed and a novel DTC strategy with a unique nonlinear perpendicular flux observer and feedback compensation scheme is proposed for obtaining a continuous, disturbance-free drive system. The simulation and experimental results demonstrate that the proposed inverter fault-tolerant PMSM DTC system is able to operate stably and continuously with acceptable static and pretty good dynamic performance.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.