Abstract
This paper presents an investigation of inverter fault-tolerant operation for a permanent magnet synchronous motor (PMSM) direct torque control (DTC) system under various inverter faults. The performance of a faulty standard 6-switch inverter driven PMSM DTC system is analyzed. To avoid the loss or even disaster caused by the inverter faults, a topology-modified inverter with fault-tolerant capability is introduced, which is reconfigured as a 3-phase 4-switch inverter. The modeling of the 4-switch inverter is then analyzed and a novel DTC strategy with a unique nonlinear perpendicular flux observer and feedback compensation scheme is proposed for obtaining a continuous, disturbance-free drive system. The simulation and experimental results demonstrate that the proposed inverter fault-tolerant PMSM DTC system is able to operate stably and continuously with acceptable static and pretty good dynamic performance.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.