Abstract

Optimization of coagulation conditions in the granulation-coagulation process for strontium removal was studied in this paper. The experimental results showed that the optimum coagulant was aluminum sulfate. The optimum coagulation conditions were dosage of 60 mg/L, coagulation time of 10 min, mixing speed of 180 r/min. The best combination method was granulation - coagulation - sedimentation. Under optimal conditions, the DF of strontium was 87 and the effluent turbidity was 1.05 NTU.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.