Abstract

An experimental study is achieved to study the thermal performance of forced unglazed solar air collector supplied with perforated absorber flat plate. The study is carried under Iraqi circumferences in Al-Ramadi city .The collector is inclined (90o) on horizontal for the simplicity of setting such type of collector on the wall building and minimize its weight. The measurement is recorded on Winter season for two sunny days and two cloudy days in (January 2012). The results show that its possible to use this type of collectors for heating in Winter time because the maximum out air temperature reach to (34oC) when ambient air temperature at (17oC) in sunny days. A good agreement is shown with the published studies Finally its obtained a good effectiveness for perforated flat plate absorber with high system efficiency.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.