Abstract
Abstract The paper evaluates extent of corrosion damage to composite glass-fibre fabric reinforcement in environment simulating concrete pore solutions (pH 12.6, 13.0, 13.5) and carbonated concrete contaminated with chlorides (pH 8.1 + Cl-) using the FT-IR and SEM/EDS techniques. Also, the effect of corrosion damage on tensile strength of segmented glass fibre as well as the presence of specific protective organic coating on glass fibre were studied. The results demonstrate local corrosion damage of samples at pH 13.5 and on the other hand high stability in environment simulating carbonated concrete and carbonated concrete contaminated with chlorides. The study also suggests unevenness of organic coating with occurrence of localized porosity which is related to aforementioned corrosion damage. Corrosion damage in FT-IR spectra manifests by changes in peaks signalling hydrolysis of protective organic coating and occurrence of peaks suggesting presence of Ca2+ rich corrosion products.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.