Abstract

Corrosion resistance of Cr - Ni (special steels) specimen is tested by electrochemical methods, numerical method of linear polarization and polarization resistance method in calcium-hypochlorite (Ca(OCl)2) solutions. With increasing of Ca(OCl)2 concentration, pH value of the solution increases, as well as active chlorine concentration and corrosion activity of the medium. According to the quantitative method of the corrosion resistance determination it can be concluded that the steels tested in 1 wt % Ca(OCl)2 solution are resistant, in 10 wt % solution constant, and in 50 wt % suspension less resistant. URANUS B6 showed the best corrosion resistance of all tested chromium - nickel steels in all tested corrosion mediums.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.