Abstract

Abstract In the present study, the effect of perforated hollow cylinders and twisted tapes on fluid flow and heat transfer behavior of a circular tube is presented for the Reynolds number (Re) range of 6000–40,000. The diametrical ratio (DR) and perforation index (PI) of compound devices are varied to determine the Nusselt number (Nu) and friction factor (f) for the combined perforated hollow cylinder (PHC) and twisted tape (TT) insert. The maximum value of Nusselt number ratio is found to be 3.19 and the minimum value of the friction factor ratio is obtained as 2.24. The PHC–TT combination provides the maximum thermal enhancement factor (TEF) of 2.43 for PI = 8%, and DR = 0.5.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.