Abstract

Uniformly distributed gas flow in the retorting suggests high thermal efficiency and high productivity for the oil shale retort using gaseous heat-carrier technology. In order to improve the gas flow distribution of Xinjiang oil shale retort, a double-deck gas inlet structure was designed and applied to it in this work. To test the efficiency of the new inlet structure, the gas flow distribution in the retorting was investigated through a three- dimensional cold model of the retort. Comparison of experimental results showed that the uniformity of gas flow distribution in the retorting increased over 8% and the sizes of dead zone decreased more than 10% when the retort was equipped with the double-deck gas inlet structure. This indicates that the application of the new gas inlet structure may significantly enhance the thermal efficiency of the pyrolysis process.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.