Abstract

Visual evoked cortical potentials induced by alternate stimulation of checkerboard pattern with the use of liquid crystal phase difference haploscope were investigated. The synchronization ratio of brain response was determined both in the group of normal binocularity and in the group with binocularity defect. The synchronization ratio of the group of normal binocularity (N = 30) is 100% at 1 Hz x 2, 98.5% +/- 3.9% at 5 Hz x 2, and 83.7% +/- 15.8% at 10 Hz x 2. On the other hand, in the group with binocularity defect, strabismus without amblyopia shows a reduction of the ratio only at the frequency of 10 Hz x 2. Anisometropic amblyopia shows a significant reduction of the ratio at 10 Hz x 2 and strabismus with amblyopia shows a remarkable reduction at 5 Hz x 2 and 10 Hz x 2. As for strabismus with or without latent binocularity, the latter cases show a significant reduction of the synchronization ratio. The reduction of synchronization ratio of VECP seems to have some relationship to the binocularity.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.