Abstract

The macrolayer thickness at critical heat flux has been determined based on the energy balance relation qCHF = ρlH fg δl. f, with measurements of the critical heat flux and the detachment frequency of vapor masses (coalesced bubbles) for various liquids at pressures from 0.05 MPa to 0.35 MPa for upward and vertical 20 mm diameter disk heaters. The macrolayer thickness correlation proposed in the fourth report of this series by Kumada and Sakashita was modified with the data obtained in the present report. Macrolayer thicknesses at low heat fluxes for water and ethanol under atmospheric pressure were also measured while changing the orientation of the heating surface from vertical to downward. The measured macrolayers at low heat fluxes were thinner than those by obtained from existing data measured by a probe method in the nucleate boiling region

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.