Abstract
In 20 patients studied under general anaesthesia, we found good agreement between gastric fluid volumes aspirated blindly and total volumes determined by fibreoptic gastroscopy (mean under-estimation 6 ml (22%); range 0-50 ml). Gastric fluid acidity measurements using an electronic pH meter and pH indicator paper also provided results with good agreement (mean difference in pH 0.1; range -0.3 to 0.5). As the use of a standardized blind gastric aspiration technique and pH indicator paper is simpler and provided sufficiently accurate measurements for clinical study purposes, we think this method is preferable.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.