Abstract
Within the frame of the HiPER reactor, we propose and study a Self Cooled Lead Lithium blanket with two different cooling arrangements of the system First Wall – Blanket for the HiPER reactor: Integrated First Wall Blanket and Separated First Wall Blanket. We compare the two arrangements in terms of power cycle efficiency, operation flexibility in out-off-normal situations and proper cooling and acceptable corrosion. The Separated First Wall Blanket arrangement is superior in all of them, and it is selected as the advantageous proposal for the HiPER reactor blanket. However, it still has to be improved from the standpoint of proper cooling and corrosion rates.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.