Abstract

In this paper, three new performance indices are proposed which can be used in order to determine the global performance of a given structure. The ASCE41-13 standard and the FEMA350 guidelines are used as representatives of, respectively, an element-oriented and a system-oriented performance-based assessment algorithm. Two ten-storeyed special steel moment frames, consisting of a regular and an irregular structure, are designed and assessed using these two algorithms. The results show that the element-oriented assessment algorithm significantly underestimates the seismic demand and capacity, especially in the case of the immediate occupancy and collapse prevention limit states. This underestimation can cause a significant drop in the estimated confidence levels.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.