Abstract

The current understanding of the thermo-mechanical response of cross-laminated timber (CLT) walls to fire is insufficiently developed. This paper presents results obtained using a novel experimental methodology on fire-exposed CLT walls under sustained loads. The findings demonstrate that global instability is likely to be the dominant failure mode for CLT walls in fire. Use of a polyurethane adhesive resulted in earlier structural failure than use of a melamine urea formaldehyde adhesive. Three-ply walls failed significantly earlier than those with five plies. The combination of these two factors caused a halving of failure time between different walls under identical heating conditions. In addition, CLT walls were found to collapse during artificially induced cooling phases. It is concluded that these findings are centrally relevant considerations for fire design of CLT.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.