Abstract
This paper presents a model for uniaxial stress–strain relationship of concrete confined by rectangular steel tubes with binding bars. The difference between concrete confinement effect provided by broad faces and that provided by narrow faces of steel tube is considered in the proposed model. Also, the binding bar arrangement in different directions is taken into account in the model. The failure criteria for concrete subjected to triaxial compression is applied to estimate the ultimate strength of concrete core. The parameters of the model are determined based on the experimental results and the calculation of complete load–strain relationship curves is conducted for axially loaded rectangular CFT specimens with binding bars using this uniaxial stress–strain relationship. The concrete core strength and stress–strain behavior of rectangular CFT columns with binding bars is found to exhibit good agreement with experimental results. In addition, the proposed model is also applicable to concrete confined by rectangular steel tubes without binding bars.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.