Abstract

BackgroundTo evaluate the stress distribution of three-element prostheses on two different implant systems (External Hexagon (EH) or Morse Taper (MT)) and with two different retention mechanisms (screw-retained or cemented), by photoelastic analysis and strain gauge analyses. Material and MethodsFour photoelastic and 24 strain gauge models of a partially edentulous maxilla were made and were divided in four groups according to connection and retention system: Group I (EH-C) – external hexagon+cement-retained prosthesis; Group II (EH-S) external hexagon+screw-retained prosthesis; Group III (MT-C) – morse taper+cement-retained prosthesis; Group IV (MT-S) – morse taper+screw-retained prosthesis. The implants were installed in the axial position, the first in the region of element 15 and the distal implant in the region of element 17. Loads of 100 N were applied on the occlusal surface of the prosthesis for 10 seconds. For the photoelasticity analysis, photographic images were taken and were evaluated according to the number of high-intensity fringes. For the strain gauge analysis, the strain gauges were positioned on the marginal crest of the implants and on the apical region, being numbered for analysis of the stress distribution in each region. The electrical signals were captured and processed by specific software. ResultsHigher concentration of tension was observed in the apical region of the implants and mainly in the distal implant, where the formation of fringes was higher. The microstrain values obtained for each group were similar: EH-C (454±18,3 µɛ); EH-S (469±94 µɛ); MT-C (466±49,8 µɛ); MT-S (460±36,6 µɛ). It was observed that apical position had higher stress concentrations for all analyzed groups. ConclusionsThe different connections and fixation mode did not interfere in the amount of tension generated in the tissue adjacent to the implant, also the region that generated the greatest amount of tension was in the apical region of the anterior implant. Key words:Dental implants, biomechanics, fixed prosthodontics.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.