Abstract

Cadmium electrodeposited Afnor 35NCD16 steel fasteners in hardened and tempered condition are used in the Indian space program. Failures were observed in size M6X17L fasteners that were under assembly load for a period of four months in an integrated test set up which involved exposure to severe humid environments. During disassembly, few of the fasteners were found to be broken at head–shank junction. Detailed metallurgical investigations carried out on failed fasteners and those, which were in assembly but did not fail, revealed their failure was caused by the synergistic effects of stress and corrosion. An attempt is made in this case history to correlate the metallurgical features collected with the failure mode of the fasteners.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.