Abstract

Thermal stress analysis for a SOFC stack under combined pressure loading and rejected heat due to stack operation is presented. An integrated temperature function of the rejected heat generated by the cell and ambient temperature settings provided a first-hand study of the effects of thermal expansion, stress and deformation for a steady-state case. The analysis involved using the temperature gradient across the cells while 20 Amps was being drawn from them. To allow for uniform thermal expansion of the stack without causing erroneous stresses, the constraints were set to allow frictionless expansion in the horizontal plane on the bottom compression plate while also fixing the bottom compression plate in the vertical plane. Displacement observations showed maximum expansion and stresses occurring at maximum temperature once the unit cell reached that temperature, however, minor changes were seen in stress variations, displacements and deflections.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.