Abstract
In this research, different techniques of repair of deficient reinforced concrete columns are compared. These include carbon fiber–reinforced polymer sheets, steel jackets, and reinforced concrete jackets. The experimental investigation includes testing of 16 deficient columns of dimensions 150 × 150 × 800 mm subjected to concentric and eccentric loading up to failure. Two main variables are considered: the load eccentricity and the strengthening technique. The experimental results showed that the three strengthening techniques used in this research significantly improved the ultimate load carrying capacity in all cases of loading. Also, in the two cases of concentric loading and big eccentricity of 150 mm, carbon fiber–reinforced polymer wrapping achieved the highest ductility and absorbed energy capacity. In addition, strengthening with reinforced concrete jacket improved the initial stiffness and toughness. The cracking load, ultimate load, and ductility of the deficient columns after strengthening were experimentally recorded and compared. The results can help the structural engineer to consider the most efficient method of repair for such columns.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.