Abstract

The objective of the present work is to carry out the strength assessment of jacket offshore wind turbine support structures subjected to progressive rupture. A defect existing in a structure made during the fabrication may turn into a small-scale rupture and because of the high-stress concentration and low-cycle fatigue load. Therefore, the ultimate load-carrying capacity of the support structure is analyzed accounting for the progress of the rupture until the leg component experiences a full rupture along its circumference. The effect of imperfection severity is also investigated. The moment–curvature relationship of the structure concerning the studied cases is presented. Furthermore, the jacket support structures, at different water depths, are also analyzed and discussed. Finally, some of the leg components are removed one by one to study the redundancy of the jacket support structure at 80-m water depth.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.