Abstract
This paper evaluates the Solar Chimney Power Plant performance subject to adverse solar radiance conditions. For that, numerical simulations are performed to estimate the optimal ratio of the turbine pressure drop to the total pressure potential (x-factor) as an independent control variable. The results show that x-factor values remain around 0.8 for periods with sufficient heat gain from sun or ground. Otherwise, x-factor values have a tendency to drop to zero. In winter, due to lower system heat gains, this trend is more accentuated.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.