Abstract

A benchmarking experiment was conducted to compare strain measurement facilities at the National Institute of Standards and Technology (NIST) and the University of Twente. The critical current of a bronze-route Nb3Sn wire, which was fabricated for the International Thermonuclear Experimental Reactor (ITER), was measured as a function of axial strain and magnetic field in liquid helium at both institutes. NIST used a Walters' spring strain device and University of Twente used a bending beam (“Pacman”) apparatus. The ITER bronze-route wire investigated had a very high irreversible strain limit that allowed comparing data over a wide range of applied strain between -1% and +1%. Similarities of the data obtained by use of the two apparatuses were remarkable, despite the many differences in their design and techniques.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.