Abstract
A benchmarking experiment was conducted to compare strain measurement facilities at the National Institute of Standards and Technology (NIST) and the University of Twente. The critical current of a bronze-route Nb3Sn wire, which was fabricated for the International Thermonuclear Experimental Reactor (ITER), was measured as a function of axial strain and magnetic field in liquid helium at both institutes. NIST used a Walters' spring strain device and University of Twente used a bending beam (“Pacman”) apparatus. The ITER bronze-route wire investigated had a very high irreversible strain limit that allowed comparing data over a wide range of applied strain between -1% and +1%. Similarities of the data obtained by use of the two apparatuses were remarkable, despite the many differences in their design and techniques.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.