Abstract

BackgroundNewborn screening for congenital adrenal hyperplasia (CAH) using 17-hydroxyprogesterone dissociation-enhanced, lanthanide fluorescence immunoassay (DELFIA) generates a large number of false-positive results. The present study aimed to improve the sensitivity of the CAH neonatal screening by including second-tier steroid profiling in dried blood spots (DBS) using liquid chromatography tandem mass spectrometry (LC-MS/MS). MethodsWe developed and validated a LC-MS/MS method for simultaneous determination of six steroids in DBS, including androstenedione, testosterone, 17-hydroxyprogesterone, 11-deoxycortisol, 21-deoxycortisol, and cortisol. Two 5-mm blood spots were eluted by internal standard working solution. We analyzed 1170 DBS samples from neonates to determine gestational age-specific reference intervals. In order to test the specificity of the second-tier method, we analyzed 707 cards with a positive screening by DELFIA. ResultsValues of intra- and inter-day precision coefficients of variance and accuracy were 2.0%–13.3% and 85.8%–114.5%, respectively. Recovery ranged from 85.0% to 106.9%. The lower limit of quantification was 0.5 ng/mL for 21-deoxycortisol, 0.25 ng/mL for 17-hydroxyprogesterone and cortisol, and 0.1 ng/mL for testosterone, androstenedione, and 11-deoxycortisol. In addition, the linearity range was 0.25–50 ng/mL (R2 > 0.99). According to the 17-hydroxyprogesterone levels and ratios of (androstenedione + 17-hydroxyprogesterone)/cortisol in the 707 positive screening samples, 77 neonates should receive recall visit. The number of false-positive results reduced by 89.1%. Totally, 18 newborns were diagnosed with 21-hydroxylase deficiency, one with P450 oxidoreductase deficiency and one with 11β-hydroxylase deficiency. With two-tier screening, the positive predictive value increased to 26.0%. ConclusionsThe second-tier steroid profiling by LC-MS/MS reduced the false-positive rate and improved the positive predictive value of CAH screening. We suggest applying this steroid profiling assay as a second-tier test for CAH screening in China.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.