Abstract

Direct steam generation (DSG) is one alternative to the current oil-based parabolic trough solar thermal power plants. Within the German research project ITES, the dynamic behavior of a DSG collector field and the interactions with the conventional power block are assessed in detail. A transient solar field model developed by DLR is used to simulate the steam temperature behavior. Artificial irradiance disturbances as well as real irradiance data are used as input to the system. The resulting main steam temperature gradients are then analyzed by Siemens considering the standards for steam turbines. This paper presents the transient simulation results of the steam temperature as well as the corresponding results of the steam turbine analysis. It is found that the occurring temperature gradients are challenging for a safe turbine operation, if a conservative control system is used. Therefore, the use of an additional thermal inertia to stabilize the steam temperature is suggested. Its impact is also analyzed and discussed in this paper.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.