Abstract

Summary form only given, as follows. This paper presents a steady-state performance analysis of a stand-alone three-phase induction generator self-excited with unbalanced capacitances and supplying unbalanced loads. Using the method of symmetrical components, the complex three-phase generator-load system is reduced to a simple equivalent passive circuit. A function minimization technique is employed to solve this equivalent circuit in order to determine the excitation frequency and magnetizing reactance. The proposed method enables practically all cases of unbalanced operation of the self-excited induction generator to be analyzed. Emphasis is next focused on single-phase loads and a special phase-balancing scheme, namely the modified Steinmetz connection (MSC), is investigated. It is shown that perfect phase balance of the SEIG can be obtained with an appropriate combination of excitation capacitances and loads. The theoretical analysis is validated by experiments on a 2.2 kW induction machine.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.