Abstract

The final status of the single module configuration for CUORE experiment will be illustrated. CUORE is a tightly packed array of 988 TeO 2 bolometers and represents one of the best approaches to search for neutrinoless double beta decay ( β β 0 ν ). TeO 2 crystals production is now well established and specific attention was dedicated to test the complete infrastructures. During the last months, dedicated measurements, referred as CCVR (Chinese Crystal Validation Run), were done at the Laboratori Nazionali del Gran Sasso (LNGS). Results obtained in CCVR runs will be presented considering the detector performances achieved and the characteristics that can be attributed to all the final detectors parts.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.