Abstract
Obstructed defecation (OD) is common and may be related to compromised pelvic floor integrity. Magnetic resonance (MR) defecography and statistical shape modeling were used to define pelvic floor shape variations, hypothesizing that State (rest vs peak evacuation) and Group (control vs case) would significantly influence shape. 16 women underwent MR defecography (9 cases vs 7 controls). Midsagittal, 2D pelvic floors were segmented and aligned by corresponding points. Principal component scores were compared using a Two-Way Mixed MANOVA. Three modes described differences between State (p < 0.001) and Group (p = 0.023). The pelvic floor shape differed significantly between women with and without OD and during evacuation.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Computer Methods in Biomechanics and Biomedical Engineering
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.