Abstract

The EF coil conductors of JT-60SA are designed with the NbTi cable in conduit conductor because the maximum magnetic field goes up to 6.2 T. The prototype NbTi conductor was developed and tested to confirm the capability of the real conductor. The prototype conductor was proven to have enough Tcs margin under the operating conditions investigated in previous test. In this study, the quench test was operated to measure the stability margin and the normal state propagation. Firstly, the MQE under the Tcs margin of 0.2 K was found to be 80 mJ/cc-strand which is almost the same as that of the previous CIC conductor to result in enough stability margins on EF coil operation. Secondly, the propagation velocity to upstream direction and downstream direction were found to be about 0.47 m/s and 0.54 m/s, respectively. Finally, the quench analysis was conducted to calculate the maximum temperature during quench. The analysis results showed that the maximum temperature reached about 70 K, which is within the permissible value of 150 K for the EF coils.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.