Abstract
Abstract Factors affecting the measurement of critical current density ( J c ) in high performance Nb 3 Sn strands are discussed. Sample holder design and sample mounting procedures are considered in the light of cryogenic heat flow considerations. Also discussed are: the steady state measurability of metastable strands at current densities ( J ) at and above their nominal J c , and mechanisms governing their quench at sufficiently high values of J greater than J c .
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.