Abstract

Residential buildings of Italy built during the last century usually show very poor energy performance. The only retrofit action widely implemented on their envelope is substitution of windows. These are very seldom coupled with mechanical ventilation, however, so their high air tightness induces serious problems of moisture condensation and mold formation – unless they are left open and their usefulness nullified. In this work, a smart combination is simulated of single flow mechanical ventilation, in itself essential to control indoor air quality and ventilation heat loss, with a relatively inexpensive sunspace built on an existing balcony, aimed to behave as a preheating chamber of the inlet cold air in winter. Moreover, mechanical ventilation is combined with an electric heat pump for hot water production, in which the outlet air flow of warm exhaust air is introduced to improve the coefficient of performance of the heat pump in the cold seasons. Energy savings allowed by such smart yet simple combination of existing technologies are discussed.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.